top of page

FURNACES

Gas Furnace

Modulating, Variable-Speed ECM Gas Furnace Up to 98% AFUE Heating Input: 60,000-120,000 BTU/h

GMVM97

image 119.png
image 119.png

Gas Furnace

Two-Stage, Variable-Speed ECM Gas Furnace Up to 96% AFUE

GMVC96

image 119.png

Gas Furnace

Two-Stage, Multi-Speed ECM Gas Furnace Up to 96% AFUE

GMEC96

image 119.png

Gas Furnace

Single-Stage Multi-Speed ECM Gas Furnace Up to 96% AFUE

GMES96

image 119.png

Gas Furnace

Single-Stage, Multi-Speed Gas Furnace Up to 96% AFUE

GMSS96

Anchor 1

Gas Furnace

 

Modulating, Variable-Speed ECM Gas Furnace Up to 98% AFUE Heating Input: 60,000-120,000 BTU/hG

 

MVM97

Benefits

Features

Heavy-duty aluminized-steel tubular heat exchanger
Efficient and quiet variable-speed Blower
Stainless-steel sloped secondary heat exchanger
Self-calibrating modulating gas valve
ComfortNet™ Communicating System compatible
Silicon Nitride igniter
Dual 7-segment display
Color-coded low-voltage terminals
Modulating gas valve
All models comply with California 40 ng/J

High reliability and quality
Faster condensate water drainage and no unit water leakage
Auto-configure for each installation
Durable and long igniter life
Self-diagnostic control board with constant memory fault code history output
Provisions for electronic air cleaner and humidifier
Energy efficient and precise comfort
Lower NOx emission
Easy Connection for EAC and Humidifier

image 146.png
image 146.png
image 146.png
image 146.png
image 146.png
image 146.png
image 146.png
image 146.png
image 146.png
image 146.png
image 146.png
image 146.png
image 146.png
image 146.png
image 146.png
image 146.png
image 146.png
image 146.png
image 146.png
image 119.png
image 146.png
image 146.png
Anchor 5

Gas Furnace

Two-Stage, Variable-Speed ECM Gas Furnace Up to 96% AFUE

GMVC96

Heavy-duty aluminized-steel tubular heat exchanger
Efficient and quiet variable-speed Blower
Stainless-steel sloped secondary heat exchanger
Silicon Nitride igniter
Dual 7-segment display
Color-coded low-voltage terminals
Two-Stage gas valve
All models comply with California 40 ng/J
Two-stage gas valve

High reliability and quality
Faster condensate water drainage and no unit water leakage
Durable and long igniter life
Self-diagnostic control board with constant memory fault code history output
Provisions for electronic air cleaner and humidifier
Quiet and Economical heating
Lower NOx emission
Tax Credit
Operates on two-stage or single-stage thermostats
Easy Connection for EAC and Humidifier

image 146.png
image 146.png
image 146.png
image 146.png
image 146.png
image 146.png
image 146.png
image 146.png
image 146.png
image 146.png
image 146.png
image 146.png
image 146.png
image 146.png
image 146.png
image 146.png
image 146.png
image 119.png

Features

Benefits

image 146.png
image 146.png
Anchor 4

Gas Furnace


Two-Stage, Multi-Speed ECM Gas Furnace Up to 96% AFUE

GMEC96

High reliability and quality
Faster condensate water drainage and no unit water leakage
Durable and long igniter life
Provisions for electronic air cleaner and humidifier
Quiet and Economical heating
Energy Efficient and quiet circulation
Lower NOx emission
Self-diagnostic control board with constant memory
Tax Credit
Operates on two-stage or single-stage thermostats
Easy Connection for EAC and Humidifier

Heavy-duty aluminized-steel tubular heat exchanger
Stainless-steel sloped secondary heat exchanger
Silicon Nitride igniter
Color-coded low-voltage terminals
Two-Stage gas valve
Multi-speed ECM blower motor with continuous fan speed
All models comply with California 40 ng/J
Fault code LED Output
Energy Star
Two-stage gas valve

image 146.png
image 146.png
image 146.png
image 146.png
image 146.png
image 146.png
image 146.png
image 146.png
image 146.png
image 146.png
image 146.png
image 146.png
image 146.png
image 146.png
image 146.png
image 146.png
image 146.png
image 146.png
image 146.png
image 146.png
image 146.png
image 146.png
image 146.png
image 119.png

Features

Benefits

image 146.png
Anchor 3

High reliability and quality
Faster condensate water drainage and no unit water leakage
Durable and long igniter life
Provisions for electronic air cleaner and humidifier
Energy Efficient and quiet circulation
Self-diagnostic control board with constant memory
Tax Credit
Simple installation and setup
Easy Connection for EAC and Humidifier
Extra option for Air flow
High static airflow capability
Lower NOx emission

Benefits

Heavy-duty aluminized-steel tubular heat exchanger
Stainless-steel sloped secondary heat exchanger
Silicon Nitride igniter
Color-coded low-voltage terminals
Two-Stage gas valve
Multi-speed ECM blower motor with continuous fan speed
Fault code LED Output
Energy Star
Two-stage gas valve

image 146.png
image 146.png
image 146.png
image 146.png
image 146.png
image 146.png
image 146.png
image 146.png
image 146.png
image 146.png
image 146.png
image 146.png
image 146.png
image 146.png
image 146.png
image 146.png
image 146.png
image 146.png
image 146.png
image 146.png
image 146.png

Gas Furnace

Single-Stage Multi-Speed ECM Gas Furnace Up to 96% AFUE

GMES96

image 119.png

Features

image 146.png
Anchor 2


Gas Furnace

Single-Stage, Multi-Speed Gas Furnace Up to 96% AFUE

GMSS96

image 119.png

High reliability and quality
Faster condensate water drainage and no unit water leakage
Durable and long igniter life
Lower NOx emission
Simple installation and setup
Quiet and simple operation

Benefits

Features

image 146.png
image 146.png
image 146.png
image 146.png
image 146.png
image 146.png

Heavy-duty aluminized-steel tubular heat exchanger
Stainless-steel sloped secondary heat exchanger
Silicon Nitride igniter
All models comply with California 40 ng/J
Single-Stage gas Valve
Single-speed inducer draft blower

image 146.png
image 146.png
image 146.png
image 146.png
image 146.png
image 146.png
bottom of page